Details:
Amphenol NETBridge cable with NTHCF012A10U dual cavity female and two Rosenberger H-MTD E6K10A-1CAZ5-Z female connectors, using LTK-40°C-105°C STP cable.
Send Inquiry

Online Store: www.premier-cable.store

Small Orders: Buy online at retail price

Bulk Orders: Contact sales for volume pricing

Description
Send Inquiry
 

Amphenol NETBridge to H-MTD Cable Assembly

 

This cable assembly is designed for automotive electronic systems that require a combination of Amphenol NETBridge and Rosenberger H-MTD interfaces. The main connection uses one NTHCF012A10U dual cavity female connector, while the opposite end is equipped with two E6K10A-1CAZ5-Z H-MTD female jack connectors.

 

The two H-MTD connectors are provided as individual branches, each maintaining its own 2 pin connection interface. This configuration allows one NETBridge connection point to accommodate two separate H-MTD connections within a single manufactured cable assembly.

 

The harness uses LTK-40°C-105°C STP shielded twisted pair cable. All connectors in this configuration are non waterproof. Eight standard cable lengths are offered from 0.1m to 5m, with additional manufacturing options available for project specific requirements.

Product Specifications

Specification Details
Total Connector Quantity 3
Branch Connector Series H-MTD
Main Connector Brand Amphenol
Main Connector Series NETBridge
Branch Connector Brand Rosenberger
Waterproof Design Non Waterproof
Cable Marking LTK-40°C-105°C STP
Cable Construction Shielded Twisted Pair
Product Type Automotive Cable Assembly
Available Lengths 0.1m, 0.5m, 1m, 1.5m, 2m, 3m, 4m, 5m
Main Connector NTHCF012A10U, Dual Cavity Female, 1pc
Branch Connector E6K10A-1CAZ5-Z, 2 Pin Female Jack, 2pcs

Connector Interface and Assembly Design

1 1

NETBridge Main Connection

 

The assembly starts with an Amphenol NTHCF012A10U dual cavity female connector. Its two contact positions are integrated into one housing, forming the main interface of the complete harness. This arrangement is intended for equipment using a dual cavity NETBridge connection while requiring a different connector family at the other end. Keeping the main interface within one connector body provides a defined connection point for the equipment side of the installation.

Twin H-MTD Female Branches

 

Two Rosenberger E6K10A-1CAZ5-Z female jack connectors form the opposite end of the assembly. Each branch uses an individual H-MTD 2 pin interface, giving the harness two separate connection points rather than one combined multi connector housing. This distinction is important when planning equipment connections, as both branch locations and mating interfaces must be considered during harness selection. The resulting configuration combines one NETBridge dual cavity female connector with two H-MTD female jack connectors in a single cable assembly.

11 1

Application and Interface Integration

Shielded Cable Construction

The specified LTK-40°C-105°C STP cable features shielded twisted pair construction. It is intended for projects specifying this cable marking and construction. Its suitability for a particular transmission rate should be confirmed against the approved cable documentation and complete system requirements.

 

Multiple H-MTD Connection Points

The two H-MTD branches can serve equipment layouts requiring separate connection positions. This configuration is useful when the installation requires two individual H-MTD female jack interfaces to be incorporated into one harness. Branch positioning and cable routing should be evaluated against the actual equipment arrangement.

 

Automotive High Speed Connectivity

The combination of NETBridge and H-MTD interfaces is intended for automotive electronic projects where different connector systems are specified across connected equipment. This assembly provides a physical cable connection between one dual cavity NETBridge interface and two H-MTD connection points. Actual transmission performance must be established using the approved cable and system specifications.

Cable Length and OEM Manufacturing

Length Options for Different Installation Layouts

The available standard lengths are 0.1m, 0.5m, 1m, 1.5m, 2m, 3m, 4m and 5m. When choosing a length, consider the distance from the NETBridge main connection to both H-MTD branch locations. Actual routing paths, installation clearance and connector orientation should be included in the measurement.

 

Custom Harness Production

Premier Cable supports OEM production of NETBridge and H-MTD cable assemblies according to customer engineering requirements. Customization can cover cable length, connector combinations, branch arrangement, cable construction and wiring specifications. Sample development and engineering verification can be arranged to check connector compatibility and physical installation requirements before volume production.

Product FAQ

How many H-MTD connectors are included ?

Two H-MTD female jack connectors are included. Each uses a 2 pin connection interface and has its own individual branch cable.

Is this assembly suitable for waterproof applications ?

The connectors are non waterproof types. Do not specify the assembly as IP67 rated or waterproof without supporting verification.

What connector combination does this cable assembly use ?

It combines one Amphenol NTHCF012A10U dual cavity female connector with two Rosenberger E6K10A-1CAZ5-Z H-MTD female jack connectors.

What cable lengths and customization options are available ?

Standard lengths range from 0.1m to 5m, with eight available options. Premier Cable also supports customized cable lengths, connector configurations and OEM manufacturing according to project requirements.

Are the NETBridge and H-MTD connectors interchangeable ?

No. NETBridge and H-MTD are different connector systems with different mating interfaces. This cable assembly integrates the specified connector types, but the mating equipment and electrical pin assignments must be checked against the approved system design.

 

Hot Tags: amphenol netbridge to h-mtd cable, China amphenol netbridge to h-mtd cable manufacturers, suppliers, factory

Send Inquiry