Products Description
M12 D-Coded to X-Coded Ethernet Cable
M12 D-Coded Male to X-Coded Male | Shielded | Cat7 | PUR | UL Style 20963

The M12 D-coded to X-coded Ethernet cable provides a direct industrial network connection between equipment using M12 D-coded and M12 X-coded Ethernet interfaces. The cable combines a straight M12 D-coded male plug with a straight M12 X-coded male plug, making it a practical solution for factory Ethernet networks, fieldbus systems, PLC control architectures and industrial machinery.
Built with shielded PUR cable, this M12 D-coded male to X-coded male cable is designed for reliable industrial data transmission in demanding automation environments. The robust PUR jacket supports applications exposed to abrasion, bending and vibration while providing oil and UV resistance for industrial installations.
The cable meets UL Style 20963 requirements and provides Cat7 electrical properties based on EN 50288-4-2. Standard lengths include 1 m, 2 m, 5 m and 10 m, while Premier Cable can manufacture custom M12 D-to-X Ethernet cable lengths for OEM equipment, machine builders and industrial network projects.
Product Specifications
Item |
Specification |
|---|---|
| Product Name | M12 D-Coded to X-Coded Ethernet Cable |
| Connector A | M12 D-Coded Male Plug, Straight |
| Connector B | M12 X-Coded Male Plug, Straight |
| Connector Configuration | M12 D-Coded Male to M12 X-Coded Male |
| Connector Orientation | Straight to Straight |
| M12 Coding | D-Coded to X-Coded |
| Connector Gender | Male to Male |
| Cable Jacket | PUR |
| Shielding | Shielded |
| Cable Standard | UL Style 20963 |
| Electrical Properties | Cat7, Based on EN 50288-4-2 |
| Network Application | Industrial Ethernet / Factory Networks / Fieldbus Systems |
| Mechanical Properties | Designed for Abrasion, Bending & Vibration |
| Special Properties | Flame Retardant, UV Resistant, Oil Resistant |
| Standard Lengths | 1.0 m / 2.0 m / 5.0 m / 10.0 m |
| Custom Lengths | Available on Request |
| Typical Applications | Factory Ethernet Networks, Fieldbus & Control Systems, Industrial Automation, Machinery & Ethernet Equipment |
Key Product Advantages
D-Code to X-Code Interface
Directly connects compatible M12 D-coded and M12 X-coded Ethernet interfaces without requiring a separate inline conversion adapter.
Shielded PUR Construction
The shielded PUR construction makes this M12 industrial Ethernet PUR cable suitable for demanding automation environments involving abrasion, bending and vibration.
Cat7 Electrical Performance
Cat7 electrical properties based on EN 50288-4-2 support reliable industrial data transmission between compatible Ethernet devices and control equipment.
Pin Assignment & Wiring
M12 X-Coded Male to M12 D-Coded Male
According to the supplied wiring drawing, four conductors from the M12 X-coded side are terminated to the four contacts of the M12 D-coded connector. The remaining M12 X-coded contacts are not used in the shown wiring configuration.
| M12 X Pin | Wire Color | M12 D Pin | Connection |
| Pin 1 | Brown | Pin 1 | 1 → 1 |
| Pin 3 | Green | Pin 2 | 3 → 2 |
| Pin 2 | Blue | Pin 3 | 2 → 3 |
| Pin 4 | Orange | Pin 4 | 4 → 4 |
| Pins 5–8 | - | - | Not Used |
The supplied wiring diagram should be confirmed against the target equipment interface before installation or production. Custom pin assignments can be evaluated according to customer drawings and application requirements.
Mating & Compatibility
M12 D-Coded to M12 X-Coded Ethernet Interfaces
This M12 D-coded to X-coded cable is intended for equipment with compatible M12 D-coded and M12 X-coded Ethernet mating interfaces. It can provide a practical network transition when different M12 coding systems are present within an industrial Ethernet architecture.
| Cable Side | Configuration |
| Connector P1 | M12 D-Coded Male Plug, Straight |
| Connector P2 | M12 X-Coded Male Plug, Straight |
| Network | Industrial Ethernet |
| Electrical Properties | Cat7 Based on EN 50288-4-2 |
| Typical Equipment | PLCs, Controllers, Industrial Ethernet Devices, Machine Networks & Field Equipment |
Before ordering an M12 D-coded male to X-coded male Ethernet cable, confirm the connector coding, mating gender, pin assignment, target equipment interface, required cable length and network requirements. Premier Cable can customize M12 Ethernet cable assemblies according to customer drawings.
Applications
Additional Application Areas
Factory Automation • PLC & Control Systems • Industrial Ethernet Networks • Fieldbus Systems • Industrial Machinery • Machine Control • Industrial Ethernet Equipment • OEM Automation Systems
FAQ
What is an M12 D-coded to X-coded Ethernet cable?
It is an industrial Ethernet cable assembly with an M12 D-coded connector on one end and an M12 X-coded connector on the other, allowing compatible equipment using different M12 coding systems to be interconnected.
What connector configuration does this cable use?
This product uses a straight M12 D-coded male plug and a straight M12 X-coded male plug, creating an M12 D-coded male to X-coded male Ethernet cable.
What type of cable jacket is used?
The cable uses a PUR jacket designed for demanding industrial applications involving abrasion, bending and vibration.
Is the M12 D to X cable shielded?
Yes. The supplied specification identifies the cable as shielded for industrial data transmission.
Is this a Cat7 cable?
The supplied specification states Cat7 electrical properties based on EN 50288-4-2. This wording is more precise than describing the assembly simply as Cat7 certified.
Does the cable meet UL Style 20963?
Yes. According to the supplied product specification, the cable meets UL Style 20963 requirements.
Where is an M12 D-coded to X-coded cable used?
Typical applications include factory Ethernet networks, fieldbus and control systems, industrial automation, PLC systems, machinery and compatible industrial Ethernet equipment.
What standard cable lengths are available?
Standard variants include 1 m, 2 m, 5 m and 10 m. Other cable lengths can be manufactured according to project requirements.
Can Premier Cable customize M12 D-to-X Ethernet cables?
Yes. Premier Cable can customize cable length, connector configuration, labeling and other cable assembly requirements according to customer drawings and equipment requirements.
What should be confirmed before ordering?
Please confirm M12 D-coding, M12 X-coding, connector gender, pin assignment, cable length, mating interface, target equipment and installation conditions before ordering.
Get In Touch

Hot Tags: m12 d-coded to x-coded ethernet cable, China m12 d-coded to x-coded ethernet cable manufacturers, suppliers, factory