Product Specifications
| Parameter | Specification |
|---|---|
| Channel Count | 1 |
| Signal Type | Coaxial |
| Orientation | Straight |
| Common Connector Gender | Female |
| Common Connector Reference | 2355843-1 |
| FAKRA Female Reference | 59Z113-000Z |
| FAKRA Male Reference | 59Z114-000Z |
| Cable Type | LEONI Dacar302-4 |
| Gender Combinations | Female to female; female to male |
| Product Type | Commercial vehicle camera harness |
| Coding | A Code on 2355843-1; FAKRA Z Code on Rosenberger type ends |
| Custom Options | Connector, cable and wiring modifications subject to engineering review |
| Connector Type | AMPSEAL16 interface coaxial female with matching female or FAKRA |
| Sealing Arrangement | Both ends sealed in version 1; equipment end sealed in versions 2 and 3 |
Available Configurations

AMPSEAL16 Interface Female to Female Coaxial Cable
Connection Structure: One 2355843-1 straight female A Code connector at each end.
Unique Difference: Uses the same sealed connector construction on both sides, retaining the equipment interface throughout the connection.
Suitable Installation: Two corresponding male ports where both connection locations require a sealed mating arrangement. The required protection level must be confirmed for the completed installation.
AMPSEAL16 Interface Female to FAKRA Female Cable
Connection Structure: One 2355843-1 female A Code connector connected to one 59Z113-000Z straight FAKRA female Z Code connector.
Unique Difference: Changes the connector system while retaining female terminations at both ends. The FAKRA end is identified as non-waterproof.
Suitable Installation: A camera or device connection routed to a corresponding FAKRA male port inside a protected enclosure or equipment compartment.


AMPSEAL16 Interface Female to FAKRA Male Cable
Connection Structure: One 2355843-1 female A Code connector connected to one 59Z114-000Z straight FAKRA male Z Code connector.
Unique Difference: Terminates in a male FAKRA interface to accept an existing female cable end.
Suitable Installation: Adaptation of an installed FAKRA female lead to equipment requiring the 2355843-1 mating interface, with the non-sealed junction kept in a protected location.
Applications & Customer Value
Commercial Vehicle Camera Installation
Camera equipment may specify a connector different from the vehicle's existing coaxial harness. A dedicated transition cable allows the interface requirement to be addressed without redesigning the complete routing layout.
Connections Across Environmental Zones
An exterior equipment connection and an interior junction can face different exposure conditions. Selecting the configuration by connection location makes the sealing boundary clear during installation planning.
Existing Harness Retention
Removing a cable routed through trim, brackets or vehicle structures can add substantial assembly work. A matching adapter may retain that route, provided the complete signal path meets the system requirements.
Service Harness Standardization
Maintenance teams need an identifiable replacement assembly. Specifying the two connector references, cable length and end labels creates a clear service part definition rather than relying on color or informal connector names.
Product Features
AMPSEAL16 Interface Housing
The pictured 2355843-1 connector combines a single coaxial connection with a surrounding latch housing. Its interface geometry must be checked against the equipment mating drawing.
Visible Retention Components
The assembly features an orange component and dark sections around the turquoise housing. Their positions and assembly sequence must follow the connector instructions, not visual assumptions.
Connector Specific Mechanical Coding
The component description identifies A Code at the common end. Mixed configurations use a separately identified FAKRA Z Code interface, so coding must be verified within each connector system.
Dacar302-4 Cable Termination
All three illustrated configurations use LEONI Dacar302-4 coaxial cable. Cable preparation, contact termination and shield connection requirements should be controlled by the approved assembly specification.
Customization Capabilities
Premier Cable supports:
Connector Customization
Connector type, gender, coding and housing design can be reviewed against the mating components. Projects can define which connection points require sealed construction and which operate inside protected compartments.
Cable Customization
Length, jacket, shielding and cable structure can be reviewed for the vehicle route. Measurement points, tolerances, protective sleeves and installation labels can be specified in the drawing.
Electrical Customization
Pin assignment, wiring definition and circuit configuration can be reviewed from the system requirements. Resistance value and power rating requirements can be evaluated where applicable; these are not established specifications of the pictured harnesses.
OEM Manufacturing
Premier Cable supports drawing review, prototypes and mass production to an approved design. Product labels and packaging can distinguish installation configurations, vehicle projects and service replacement parts.
Product FAQ
Q1. Does "AMPSEAL16 interface" mean this cable has sixteen electrical contacts?
The supplied product is described as a single cavity coaxial assembly. The interface name should not be interpreted as the number of populated electrical connections.
Q2. Can the turquoise housing color be used to select the coding?
No. Use the complete connector reference and mating drawing. The supplied images contain conflicting generic coding text, so color alone is insufficient for selection.
Q3. Can this harness be used with any commercial vehicle camera?
No specific camera compatibility is confirmed. Provide the camera connector, receiving equipment reference, signal requirements and complete cable route for evaluation.
Q4. Is the complete harness rated IP67 Waterproof?
A numerical protection rating has not been provided. An IP67 Waterproof claim requires confirmation of the connector specification, mating conditions and completed assembly construction.
Q5. What information is needed for an OEM quotation?
Specify the version, quantity, required length and measurement points. Include mating connector drawings, installation exposure, electrical acceptance criteria and any labeling or packaging requirements.
Hot Tags: automotive fakra coaxial cable, China automotive fakra coaxial cable manufacturers, suppliers, factory