Twin FAKRA Z Code Breakout Cable

Twin FAKRA Z Code Breakout Cable

Twin FAKRA Z Code Breakout Cable

Twin FAKRA Z Code Breakout Cable suppliers

Twin FAKRA Z Code Breakout Cable suppliers

Twin FAKRA Z Code Breakout Cable
Details:
FAKRA Z Code breakout cable with a 59Z115-000-Z dual cavity female end and two 59Z113-000-Z female or two 59Z114-000-Z male ends. RG174 LL coax carries two separate automotive video paths.
Send Inquiry

Online Store: www.premier-cable.store

Small Orders: Buy online at retail price

Bulk Orders: Contact sales for volume pricing

Description
Send Inquiry
 

This FAKRA Z Code breakout cable connects one dual cavity port to two separate single cavity mating points. The straight 59Z115-000-Z female housing groups both coaxial paths at the module. At the other end, each path has its own straight FAKRA connector, so the two leads can reach ports in different locations.

 

The branch ends come in two configurations. Use two female ends for male mating ports, or two male ends for female mating ports. Both configurations use RG174 LL coax and water blue Rosenberger style compatible housings without waterproof sealing.

Product Specifications

Item Specification
Connector Coding Z Code
Connector Sealing Unsealed
Housing Color Water Blue
Coaxial Cable Temperature Range −40°C to 105°C
Cable Type RG174 LL Coaxial Cable
Connector Style Rosenberger Style Compatible
Product Type Automotive FAKRA Coaxial Breakout Cable
Common End Straight FAKRA dual cavity female, 59Z115-000-Z
Application Automotive video harness integration and bench testing
Length Options 0.1m, 0.5m, 1m, 1.5m, 2m, 3m, 4m, 5m, 6m, 7m, 8m, 9m, 10m
Male Branch Option Two straight FAKRA single cavity male connectors, 59Z114-000-Z
Female Branch Option Two straight FAKRA single cavity female connectors, 59Z113-000-Z

Available Configurations

3 1
Version 1

Dual Cavity Female to Two Single Cavity Female Cable

 

Connection Structure: One straight 59Z115-000-Z dual cavity female connector to two straight 59Z113-000-Z single cavity female connectors.

 

Unique Difference: The two female branch ends let installers route each coaxial path to a separate male port while keeping both paths in one housing at the module.

 

Installation Fit: Choose this configuration when the two branch connections terminate at compatible male FAKRA single cavity ports, such as separate ports on an automotive video test fixture.

Version 2

Dual Cavity Female to Two Single Cavity Male Cable

 

Connection Structure: One straight 59Z115-000-Z dual cavity female connector to two straight 59Z114-000-Z single cavity male connectors.

 

Unique Difference: The two male branch ends can mate with existing female FAKRA leads individually. This configuration can bring two separately routed leads into one dual cavity connection at the module.

 

Installation Fit: Choose this configuration when both branch connections need to mate with compatible female FAKRA single cavity connectors on an existing vehicle harness or bench setup.

4 1

Automotive Video Harness Integration

Route Each Coaxial Path to Its Own Port

When the module groups two coaxial positions into one dual cavity housing, the breakout keeps that connection together and gives each path its own lead at the opposite end. The leads can reach separate ports on a test fixture or follow different routes through a vehicle harness.

 

Specify the Two Paths on the Drawing

For an assembly drawing, identify which cavity at the dual cavity end connects to each single cavity lead. If the leads must reach different locations, specify each required length and where the measurements start and end. Branch labels can be included in the inquiry so assembly and test teams can identify the paths during installation.

OEM Ordering Information

Branch Connector Selection

Both configurations use the 59Z115-000-Z dual cavity female connector. Specify two 59Z113-000-Z female branch connectors for male mating ports, or two 59Z114-000-Z male branch connectors for female mating ports. Include the mating part numbers if available so fit can be checked before quoting.

 

Cable Length and Cavity Mapping

Mark each lead's required length and measurement points on the assembly drawing, especially if the branches follow different routes. Identify which cavity at the dual cavity end connects to each branch. If the leads need to be identified during installation or testing, include the label text and placement.

 

Cable Type and Order Quantity

RG174 LL is the standard coaxial cable for this assembly. If your drawing calls for RTK031, list that cable type in the inquiry so the cable construction can be reviewed before quoting. Include the sample quantity and estimated production quantity so both order quantities can be quoted separately.

Product FAQ

Does the temperature range cover the entire assembly ?
The listed range of −40°C to 105°C applies to the RG174 LL coaxial cable. Include any complete assembly temperature requirement in your inquiry.

Where can I install this cable ?
The connector housings are unsealed. Use the assembly in protected locations such as enclosed equipment areas or indoor test fixtures.

Does the cable divide one video signal into two outputs ?
The cable routes two separate coaxial paths from the dual cavity housing to two individual connectors. Each branch corresponds to one cavity at the common end.

How do I choose the branch connector type ?
Choose the 59Z113-000-Z female branch ends for compatible male mating ports. Choose the 59Z114-000-Z male branch ends for compatible female mating connectors. Confirm Z Code and the mating housing on both connections.

 