7 Pole Marked Luminaire Connection Interface
PCM-2067-7P is a 7 pole pluggable luminaire connector for lighting equipment designs that need a matching connection interface with visibly identified terminal positions.
The connector housing is marked N, an earth symbol, 1, 2, 3, + and −. This marked layout is the defining feature of the 7P version: it provides seven corresponding reference positions across the two mating connector halves rather than an unmarked multi-pole interface.
Use PCM-2067-7P when the electrical drawing of the finished equipment already requires this seven-position layout. The housing marks help users verify position correspondence during wiring and mating; the final circuit function of every position must follow the wiring legend and requirements of the completed lighting product.
Marked 7-Position Layout

PCM-2067-7P Mated Assembly

Housing Marking Reference View
| N | Earth Symbol | 1 | 2 | 3 | + | − |
| Housing reference | Housing reference | Numbered position | Numbered position | Numbered position | Marked position | Marked position |
Terminal-marking note: N, the earth symbol, 1, 2, 3, + and − are physical marks on the connector housing. They identify positions for matching and verification. They do not replace the electrical schematic of the finished luminaire and should not be treated as a universal wiring assignment.
Why Select the 7P Marked Version?
Select this configuration when a project requires seven separately identified connection positions, including a numbered group and a pair of polarity-marked positions. The marked arrangement can be useful where the equipment design needs installers or production personnel to check corresponding routes visually before the two connector halves are joined.
The 7P version should be specified from the circuit layout first, not simply selected because it has more positions than a 5P connector. Confirm that the complete equipment drawing calls for all seven housing marks and that the connector geometry fits the available space.
Mating Verification Sequence
| 1. Read the Wiring Legend Confirm the project requires the N, earth, 1, 2, 3, + and − position layout |
2. Check Both Halves Verify corresponding housing marks before the connector is mated |
3. Confirm Mechanical Orientation Check the connection direction and available installation space |
4. Test the Completed Assembly Verify continuity and the final wiring arrangement before use |
Technical Reference
Part No.
PCM-2067-7P
Connector Format
7 Pole Two-Piece Pluggable Connector
Rated Voltage / Current
450V / 16A
Conductor Range
1.5–2.5 mm²
Withstand Voltage
AC 2500V for 1 Minute
Insulation Resistance
500MΩ at DC 500V
Information to Confirm Before Ordering
| Project Item | What to Confirm |
| Terminal Layout | The equipment drawing uses N, earth, 1, 2, 3, + and − as the required seven-position reference layout. |
| Conductor Requirement | The selected conductor falls within the stated 1.5–2.5 mm² range. |
| Mating Condition | Both connector halves use the matching marking order and required orientation. |
| Installation Envelope | The drawing dimensions and connector direction suit the available enclosure space. |
Dimensional Reference

The drawing shows the seven-position housing layout, mating construction, and overall dimensions. Confirm the complete wiring arrangement and installation condition before production use.
Need a 7-Pole Marking Layout Confirmed for Your Lighting Design?
Hot Tags: 7 pole pluggable luminaire connector 450v 16a, China 7 pole pluggable luminaire connector 450v 16a manufacturers, suppliers, factory