Details:
PCM-ZC-0188 is a 4-port GEMnet to 4× MATEnet Z-Code automotive Ethernet breakout cable assembly. It uses a TE 1-2386629-4 GEMnet Z-Code interface on one side and four TE 2302510-9 MATEnet Z-Code interfaces on the breakout side, providing four separate high-speed data connection paths in a compact fan-out harness.
Send Inquiry

Online Store: www.premier-cable.store

Small Orders: Buy online at retail price

Bulk Orders: Contact sales for volume pricing

Description
Send Inquiry
 4 Port GEMnet to 4 MATEnet Z Code Automotive Ethernet Breakout Cable

4-Port GEMnet to Four MATEnet Connections

The PCM-ZC-0188 cable assembly uses a GEMnet Z-Code connector based on TE 1-2386629-4 at the main interface and four MATEnet Z-Code connectors based on TE 2302510-9 at the breakout side.

Instead of combining or duplicating one data channel, the harness routes four separate pin pairs from the multi-port GEMnet interface to four individual MATEnet branches.

Multi-Channel Breakout Harness Design

The four-port breakout structure is useful when a consolidated GEMnet connector must be distributed into four separate MATEnet interfaces while maintaining defined channel-to-branch wiring.

Each branch uses its own conductor pair and shield connection according to the assembly drawing, helping keep the channel arrangement clear during equipment integration and cable installation.

GEMnet to MATEnet 1 to 4 Breakout Cable Assembly

Key Features

4-Port GEMnet Interface

One GEMnet Z-Code interface routes four independent channel pairs through a single multi-port connector.

4 × MATEnet Z-Code

Four individual MATEnet Z-Code branches provide separate connection points on the breakout side.

100Ω Nominal Impedance

The cable assembly is specified with 100-ohm nominal impedance.

Dacar 686-3 Cable

Uses LEONI Dacar 686-3 Ethernet cable throughout the four breakout branches.

Product Specifications

Part Number PCM-ZC-0188
Product Type GEMnet to MATEnet Automotive Ethernet Breakout Cable
Main Connector 4-Port GEMnet Jack Z-Code
GEMnet Reference TE 1-2386629-4
Breakout Connectors 4 × MATEnet Jack Z-Code
MATEnet Reference TE 2302510-9
Cable LEONI Dacar 686-3 Ethernet Cable
Impedance 100Ω Nominal
Frequency Range DC–10 GHz
Hi-Pot 500 VRMS Minimum
Continuity 100% Tested
Cable Retention 110 N Minimum
Temperature Range -40°C to +105°C
Standard Lengths 0.5 m / 1 m / 2 m

Defined Branch Routing for Multi-Port Connections

The fan-out construction allows one consolidated multi-port connector to interface with four individually positioned MATEnet connections.

This arrangement can simplify harness routing where four individual device-side connectors must be connected back to one multi-port GEMnet interface.

4 Channel GEMnet MATEnet Fan Out Harness

Available Cable Lengths

Part Number Nominal Length Tolerance
PCM-ZC-0188-0.5M 500 mm ±15 mm
PCM-ZC-0188-1M 1000 mm ±20 mm
PCM-ZC-0188-2M 2000 mm ±20 mm

Typical Connection Scenarios

PCM-ZC-0188 is intended for systems where one compatible 4-port GEMnet interface must connect to four separate MATEnet Z-Code interfaces.

Multi-Port Equipment Connection

Connect a compatible 4-port GEMnet equipment interface to four individual MATEnet cable-side connections.

Harness Breakout Routing

Separate the four channel pairs into individual cable branches for more flexible equipment-side routing.

Test & Integration Harness

Useful where individual channel access is required between compatible GEMnet and MATEnet interfaces during integration or testing.

PCM-ZC-0188 Technical Drawing

PCM-ZC-0188

PCM-ZC-0188 connector configuration, branch routing, electrical requirements and cable length reference.

What to Confirm Before Ordering

For equipment-specific projects, confirm the connector references and channel assignment before ordering the harness.

Connector Interface

Confirm the required GEMnet and MATEnet Z-Code mating interfaces and reference part numbers.

Channel Mapping

Confirm the required mapping between each GEMnet pin pair and the corresponding MATEnet branch.

Cable Length

Select the appropriate assembly length according to the installation and equipment layout.

GEMnet & MATEnet Cable Assemblies

Need a GEMnet to MATEnet Cable Assembly?

Send us the required GEMnet interface, MATEnet interface, branch configuration, cable length, pin mapping and project quantity. Premier Cable can review the connection requirements for your automotive Ethernet cable assembly project.

Contact Us

Hot Tags: 4-port gemnet to 4× matenet automotive ethernet breakout cable, China 4-port gemnet to 4× matenet automotive ethernet breakout cable manufacturers, suppliers, factory

Send Inquiry